Sign In | Join Free | My himfr.com
Home > Air Test Instruments >

AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment

Beijing Ifan Peng Instrument Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
     
    Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers
    • Buy cheap AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment from wholesalers

    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment

    Ask Lasest Price
    Brand Name : IVANPER
    Model Number : Phg-210fs
    Supply Ability : 1000 Bag/Bags per Month
    Price : $160.00/units >=2 units
    • Product Details
    • Company Profile

    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment

    Product Description
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    Specification
    Packing & Delivery
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    Company Profile

    Phg-2250 industrial pH meter is an intelligent upgraded product of industrial pH meter, which can continuously measure and control
    the pH value of sewage. This device is applicable to urban sewage treatment plant, chemical industry, printing and dyeing, paper
    making, pharmaceutical industry, electroplating, environmental protection and other fields.
    According to the environment and characteristics of the water industry, combined with the international power supply standard, the
    electrical design code for special environment is considered, and the selection of 220V AC (phg-2250a) and safe low voltage 24V
    AC, 24V DC (phg-2250b) power supply is added.

    Main features:
    128 * 64 lattice LCD, large screen dual channel display
    Three configuration modes: dual pH, dual ORP, one pH and one ORP
    Factory standard configuration Chinese interface, language menu
    It can measure the pH / ORP of two channels, control the upper and lower limits
    It can be set to automatic temperature compensation or manual temperature compensation
    PH high limit alarm, low limit alarm two-way relay, the hysteresis can be adjusted freely
    The audible alarm can be switched on and off through the interface options
    LCD backlight can choose energy-saving mode and turn off automatically at fixed time
    High performance CPU, good EMC performance
    Password management function to prevent misoperation of non professionals

    Main technical indicators:
    Measuring channel: two channels
    Measurement range: pH (0 – 14 pH); ORP (- 1999 - + 1999 MV)
    Accuracy: + 0.02 pH; + 1 MV
    Resolution: 0.01ph; 1mV
    Stability: < 0.02 pH / 24h; < 3 MV / 24h
    PH standard solution: 4.01/6.86/9.18
    Display mode: 128 * 64 dot matrix LCD
    Temperature compensation: 0 – 100 ℃ manual / automatic (ntc10k)
    Alarm output: two high and low limit alarm contacts, four sets of normally open contact relays (3a / 250 V AC),
    Power supply: AC 220V ± 10% 50Hz
    Power consumption: ≤ 3W
    Environmental conditions: (1) temperature 0-60 ℃ (2) humidity ≤ 85% RH
    Boundary dimension: 96 × 96 × 110mm (H × w × d)
    Opening size: 92 × 92mm (H × w)
    Recommend Products
    Packing & Delivery
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    Company Profile

    Founded in 2011, Beijing Ifpen Instrument Enterprise, which is adjacent to the beautiful political and cultural center, is located in Beijing Daxing Industrial Development Zone. Our company has a professional, innovative technical team and a standardized production team. Over the years, we have been achieved zero breakthrough in turbulence jump by committing to the production and R&D of industrial instruments and meters and focusing on the R&D and exploration in the field of "wind speed and air volume". After the continuous evolution of the hot ball, hot wire and hot film principles, as well as the exclusive secondary calibration method, we are well-known in the industry as high precision and high stability, breaking the conventional method of using the differential pressure principle to detect air volume in the traditional industry and breaking through the error value of micro wind speed measurement. IVAN has persisted in serving new and old customers with "Innovation, Quality, Integrity" since its foundation. "The heart of innovation, serving the world", IVAN focuses on R&D, provides high-quality products and services, and is committed to the quality road of production enterprises.
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    Exhibition
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    Certifications
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment
    FAQ
    Q1. Why choose IVAN?
    A: Founded in 2011, IVAN is a leading manufacturer in the instrumentation industry, providing OEM & ODM services.
    Q2. Could I get sample?
    A: Yes, sample order is acceptable, but the sample cost and freight need to be charged.
    Q3. What is the term of payment?
    A: 100% payment in advance by T/T.
    Q4. What is the delivery time of IVAN?
    A: Generally, it will be 7-15 working days after receiving payment.
    Q5. How about IVAN validity of quotation?
    A: It is usually 30 days because the freight and exchange rates may fluctuate.
    Q6. What is your normal delivery way?
    A: Goods will be sent by DHL/FEDEX/UPS/EMS/TNT or other proposed forwarders.
    Q7. How about the package?
    A: Standard export wooden case or normal export carton.
    Q8. Do you test all your goods before delivery?
    A: Yes, we will test 100% before delivery.
    If you have any questions, please feel free to contact us!
    Quality AC 220 V ± 10% 50 Hz Power Supply PH ORP Meter for Drinking Water Treatment Equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Ifan Peng Instrument Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)